The Retractable Chemical Injection Quill is an essential instrument for the efficient delivery of chemicals into pipelines and processing systems. Its design facilitates straightforward insertion and removal, enabling precise chemical distribution without halting operations. The quill’s retractable functionality permits safe maintenance and inspection. Key industries, including oil and gas, water treatment, and chemical processing, depend on this tool to boost system performance and safeguard equipment from corrosion and scaling. Thanks to its robust construction and flexibility to fit different pipeline sizes, the quill is vital for preserving optimal flow and ensuring system integrity.
Specifications
Category | Details |
Product Information | |
Product Name | Chemical Injection Quill |
Brand Name | EMT Pigging |
Condition | New |
Type | Injection & Sampling System |
Certification | ISO 9001 |
Warranty | 1.5 years |
Place of Origin | Liaoning, China |
Physical Specifications | |
Weight (KG) | 5 |
Package Size (cm) | 35 x 40 x 60 |
Gross Weight (Package, kg) | 8 |
Material and Construction | |
Sealing Material | Fluororubber |
Solid Plug Assembly | 316L Stainless Steel |
Injection Tube | 316L Stainless Steel |
NPT Nozzle | 316L Stainless Steel |
Flange Material | ASTM A105N |
Operational Parameters | |
Working Temperature (°C) | -20 to 200 |
Operation Temperature (°C) | -20 to 150 |
Working Pressure (LB) | 150LB, 300LB, 600LB, 900LB, 1500LB |
Pressure Rating (PSI) | 6000 PSI or as per Flange Size |
Applications
The EMT Retractable Chemical Injection Quill serves multiple applications across various industries. It excels in the oil and gas sectors by precisely injecting corrosion inhibitors and scale preventatives. Additionally, it supports the petrochemical industry, where accurate chemical dosing is critical to process efficiency and product quality. Water treatment facilities also benefit from its ability to inject coagulants and disinfectants effectively. Moreover, its retractable design allows for easy maintenance without disrupting system operations, which is crucial in continuous production environments. Thus, this quill proves indispensable for ensuring optimal chemical management and protection of industrial equipment.
Features of the Retractable Chemical Injection Quill
The Retractable Chemical Injection Quill is equipped with numerous features that enhance its functionality and safety. Its retractable nature allows for easy maintenance and inspection without the need to shut down the system, promoting uninterrupted operations. Constructed from materials that resist corrosion, it stands up to demanding environments with ease. The quill ensures precise chemical dosing, improving the efficiency of processes. It also features an adjustable insertion depth, making it adaptable to a variety of pipeline dimensions. The simplicity of its installation and removal adds to its operational convenience. Furthermore, it includes safety mechanisms that prevent leaks and ensure the secure handling of chemicals, positioning it as a critical device for effective chemical management in various industrial settings.
Why Choose EMT Retractable Chemical Injection Quill
Opting for the EMT Retractable Chemical Injection Quill brings multiple benefits. Its construction from corrosion-resistant materials guarantees durability and sustained performance, even in harsh conditions. The quill’s retractable design facilitates straightforward maintenance and inspections without halting system operations. It delivers chemicals with precise accuracy, which not only enhances process efficiency but also safeguards equipment. Its versatility is evident in its adjustable insertion depth, suitable for different pipeline sizes. The quill’s design prioritizes ease of installation and incorporates safety features that prevent any chemical leaks, ensuring safe operations. These attributes make the EMT Retractable Chemical Injection Quill an excellent choice for industries that require dependable and effective chemical injection capabilities.
Selection Model
Model | |||||||||||||||||||||||||||
SI | Chemical Injector Quill | ||||||||||||||||||||||||||
-Code | Plug | ||||||||||||||||||||||||||
Pxxx | Type | Material | Sealing Material | ||||||||||||||||||||||||
0 | No Request | 0 | CS | 0 | No Request | ||||||||||||||||||||||
1 | Hollow Plug Body | 1 | 316SS | 3 | DSS | 1 | Viton O-Ring / PTFE Primary Packing | ||||||||||||||||||||
2 | Solid Plug Body | 2 | 316LSS | 4 | INCONEL | 2 | HNBR | ||||||||||||||||||||
– Code | Injection Nut | ||||||||||||||||||||||||||
Nxx | Connection Size | Material | |||||||||||||||||||||||||
0 | i.e. No Request | 0 | i.e. CS | ||||||||||||||||||||||||
1 | i.e. 1/4″ | 1 | i.e. 316SS | 3 | i.e. DSS | ||||||||||||||||||||||
2 | i.e. 1/2″ | 2 | i.e. 316LSS | 4 | i.e. INCONEL | ||||||||||||||||||||||
– Code | Injection Tube | ||||||||||||||||||||||||||
Sxxx-Lx″ | Connection Size | Material | Nozzle | Line size(x″) | |||||||||||||||||||||||
0 | No Request | 0 | CS | 0 | i.e. No Request | The most effective position for injection is generally at the center of the pipe | |||||||||||||||||||||
1 | i.e. 1/4″ | 1 | i.e. 316SS | 1 | i.e. Open | ||||||||||||||||||||||
2 | i.e. 1/2″ | 2 | i.e. 316LSS | 2 | i.e. Quill | ||||||||||||||||||||||
3 | i.e. DSS | 3 | i.e. Cap & Core | ||||||||||||||||||||||||
4 | i.e. INCONEL | ||||||||||||||||||||||||||
– Code | Nipple and Valve(or end Flange)of Tee | ||||||||||||||||||||||||||
Txx | Connection Size | Material | |||||||||||||||||||||||||
0 | i.e. No Request | 0 | i.e. CS | ||||||||||||||||||||||||
1 | i.e. 1/4″Nipple | a | i.e. 1/4″Nipple and Valve | 1 | i.e. 316SS | ||||||||||||||||||||||
2 | i.e. 1/2″Nipple | b | i.e. 1/2″Nipple and Valve | 2 | i.e. 316LSS | ||||||||||||||||||||||
3 | i.e. 3/4″Nipple | c | i.e. 3/4″Nipple and Valve | 3 | i.e. D SS | ||||||||||||||||||||||
4 | i.e. 1″Nipple | d | i.e. 1″Nipple and Valve | 4 | i.e. INCONEL | ||||||||||||||||||||||
5 | i.e. 1/4″Flange | e | i.e. 1/4″Nipple end Flange | ||||||||||||||||||||||||
6 | i.e. 1/2″Flange | f | i.e. 1/2″Nipple end Flange | ||||||||||||||||||||||||
7 | i.e. 3/4″Flange | g | i.e. 3/4″Nipple end Flange | ||||||||||||||||||||||||
8 | i.e. 1″Flange | h | i.e. 1″Nipple end Flange | ||||||||||||||||||||||||
For Example, SI-P221-N12-S122-L4″-T22 | |||||||||||||||||||||||||||
SI:e.g. Sampling & Injection Assembly, | |||||||||||||||||||||||||||
P221: e.g. Solid Plug Body in 316LSS Viton O-Ring and PTFE Primary Packing, | |||||||||||||||||||||||||||
N12:e.g. injection Nut Connection Size is 1/4″and Material is 316LSS, | |||||||||||||||||||||||||||
S122:e.g. injection Tube Connection Size is 1/4″ and Material is 316LSS. Type of nozzle is quills | |||||||||||||||||||||||||||
L4″:For 4″pipe. | |||||||||||||||||||||||||||
T22: Nipple of Tee Connection Size is 1/2″, Nipple material is 316LSS |
There are no reviews yet.